Jonweb FA, Japan FA, 日本工控网

Always Changes For The Better! 

Fuji Factory Automation Products: Fuji PLC, Fuji LVS, Fuji PLC, Fuji Inverter, Fuji Servo, Fuji HMI, Fuji POD Fuji Inverter, Fuji PLC, Fuji Servo, Fuji HMI, LVS, Come From:JonWeb Technology! 
  中文访问 HOME CONTACT Selling  Price Fuji Inverter Fuji PLC Fuji HMI Fuji Power Distribution Fuji Servo User Manual
 
Jonweb FA:
Siemens PLC & Siemens HMI, Siemens Inverter
Allen Bradley PLC
Mitsubishi PLC & Mitsubishi Inverter
Semiconductor
Yaskawa Inverter
Fuji AC Servo System
Cisco Router & Switche
 
On Requested:
Schneider PLC
Mean Well
APC UPS Power Supply
Proface HMI
LG PLC / Inverter
VIPA PLC / HMI
Sanyo Denki
BTB Inverter
Fluke Meters
Tektronix Oscilloscopes
Agilent
Hioki Tester
Panasonic
Omron
Toshiba
Hitachi
Idec
Sanken
Koyo
Meiden
Nikki Denso
Keyence
Oriental
 
Also Supply:
 -> 枕头 / 床垫
 -> Fuel Additive - STR2020
Contact Method
China/Beijing
    TeL:+86-10-86360099
            +86-10-62988280
    Fax:+86-10-62985883
MSN:
  cn5130@hotmail.com 
Email :
  ZhengJon@yahoo.com 
Any Call:
  +86-13001958500
Skype ID:  japanfa.com

More Detail...

 
GuestBook
  Send messages to us online.
Send messages to us online.
 
  
Sell your FA to China?
 
> Fuji Products Center   >  Fuji Inverters > FRENIC-ECO  > Standard specifications
Standard specifications Three-phase 200V series
Item
Specifications
Type (FRNF1S-2A) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110
Applicable motor rating [kW] (*1) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110
Output ratings Rated capacity[kVA] (*2) 1.6 2.6 3.8 6.2 8.3 11 16 21 25 30 40 49 59 75 102 121 146
Rated voltage[V] (*3) Three-phase, 200V/50Hz, 200, 220, 230, 240V/60Hz (With AVR function)
Rated current[A] (*4) 4.2 7.0 10 16.5 22.5 29 42 55 68 80 107 130 156 198 270 320 384
Overload capability 120% of rated current for 1min
Rated frequency[Hz] 50, 60Hz
Input ratings Phases, voltage,
frequency
Main power supply Three-phase, 200 to 240V, 50/60Hz Three-phase, 200 to 220V/50Hz
Three-phase, 200 to 230V/60Hz
Auxiliary control
power input
Single-phase, 200 to 240V, 50/60Hz Single-phase, 200 to 220V/50Hz
Single-phase, 200 to 230V/60Hz
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance: 2% or less (*8)), Frequency: +5 to -5%
Rated current[A] (*5) (with DCR) 3.2 6.1 8.9 15.0 21.1 28.8 42.2 57.6 71.0 84.4 114 138 167 203 282 334 410
(without DCR) 5.3 9.5 13.2 22.2 31.5 42.7 60.7 80.1 97.0 112 151 185 225 270
-
-
-
Required power supply capacity[kVA] (*6) 1.2 2.2 3.1 5.3 7.4 10 15 20 25 30 40 48 58 71 98 116 142
Braking Torque[%] (*7)
20
10 to15
DC injection braking Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
DC REACTOR(DCR) Option Standard
Applicable safety standards UL508C, C22.2No.14, EN50178:1997(Applying)
Enclosure(IEC60529) IP20 UL close type IP00 UL open type
Cooling method Natural cooling Fan cooling
Weight / Mass[kg]         3.3 5.6 5.6 6.6 9.3 9.5 11.7 23 31 34 41    
(*1) Fuji's 4-pole standard motor
(*2) Rated capacity is calculated by assuming the output rated voltage as 220V for three-phase 200V series.
(*3) Output voltage cannot exceed the power supply voltage.
(*4) When setting the carrier frequency (F26) to 1 kHz, reduce the load to 80% of its rated value.
(*5) Calculated under Fuji-specified conditions.
(*6) Obtained when a DC REACTOR is used.
(*7) Average braking torque without optional braking resistor (Varies with the efficiency of the motor.)
(*8) Voltage unbalance [%] =(Max. voltage [V] - Min. voltage [V])/(Three-phase average voltage [V])x 67 (IEC61800-3(5.2.3))
  If this value is 2 to 3%, use an AC REACTOR.

Standard specifications Three-phase 400V series (0.75 to 55kW)
Item
Specifications
Type (FRNF1S-4A) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Applicable motor rating [kW](*1) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Output ratings Rated capacity[kVA](*2) 1.9 2.8 4.1 6.8 9.5 12 17 22 28 33 44 54 64 77
Rated voltage[V](*3) Three-phase, 380, 400V/50Hz, 380, 400, 440, 460V/60Hz (with AVR function)
Rated current[A](*4) 2.5 3.7 5.5 9.0 12.5 16.5 23 30 37 44 58 71 84 102
Overload capability 120% of rated current for 1min
Rated frequency[Hz] 50, 60Hz
Input ratings Phases, voltage,
frequency
Main power supply Three-phase, 380 to 480V, 50/60Hz Three-phase, 380 to 440V/50Hz
Three-phase, 380 to 480V/60Hz
Auxiliary control
power input
Single-phase, 380 to 480V, 50/60Hz Single-phase, 380 to 440V/50Hz
Single-phase, 380 to 480V/60Hz
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance: 2% or less(*8)), Frequency: +5 to -5%
Rated current[A](*5) (with DCR) 1.6 3.0 4.5 7.5 10.6 14.4 21.1 28.8 35.5 42.2 57.0 68.5 83.2 102
(without DCR) 3.1 5.9 8.2 13.0 17.3 23.2 33.0 43.8 52.3 60.6 77.9 94.3 114 140
Required power supply capacity[kVA](*6) 1.2 2.2 3.1 5.3 7.4 10 15 20 25 30 40 48 58 71
Braking
Torque[%](*7)
20
10 to 15
DC injection braking Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
DC REACTOR(DCR) Option
Applicable safety standards UL508C, C22.2No.14, EN50178:1997(Applying)
Enclosure (IEC60529) IP20 UL close type IP00 UL open type
Cooling method Natural cooling Fan cooling
Weight / Mass[kg]         3.3 5.6 5.7 6.6 9.2 10.3 11.7 23 23 30
(*1) Fuji's 4-pole standard motor
(*2) Rated capacity is calculated by assuming the output rated voltage as 440V for three-phase 400V series.
(*3) Output voltage cannot exceed the power supply voltage.
(*4) When setting the carrier frequency (F26) to 1 kHz, reduce the load to 80% of its rated value.
(*5) Calculated under Fuji-specified conditions.
(*6) Obtained when a DC REACTOR is used.
(*7) Average braking torque without optional braking resistor (Varies with the efficiency of the motor.)
(*8) Voltage unbalance [%] =(Max. voltage [V] - Min. voltage [V])/(Three-phase average voltage [V])x 67 (IEC61800-3(5.2.3))
  If this value is 2 to 3%, use an AC REACTOR.

Standard specifications Three-phase 400V series (75 to 500kW)
Item
Specifications
Type (FRNF1S-4A) 75 90 110 132 160 200 220 280 315 355 400 450 500
Applicable motor rating[kW](*1) 75 90 110 132 160 200 220 280 315 355 400 450 500
Output ratings
Rated capacity[kVA](*2) 105 128 154 182 221 274 316 396 445 495 584 640 731
Rated voltage[V](*3) Three-phase, 380, 400V/50Hz, 380, 400, 440, 460V/60Hz (with AVR function)
Rated current[A](*4) 139 168 203 240 290 360 415 520 585 650 740 840 960
Overload capability 120% of rated current for 1min
Rated frequency[Hz] 50, 60Hz
Input ratings Phases, voltage,
frequency
Main power supply Three-phase, 380 to 440V, 50Hz
Three-phase, 380 to 480V, 60Hz
Auxiliary control
power input
Single -phase, 380 to 480V, 50/60Hz
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance: 2% or less (*8)), Frequency: +5 to -5%
Rated current[A](*5) (with DCR) 138 164 201 238 286 357 390 500 559 628 705 789 881
(without DCR) - - - - - - - - - - - - -
Required power supply capacity[kVA](*6) 96 114 140 165 199 248 271 347 388 435 489 547 611
Braking
Torque[%](*7) 10 to 15
DC injection braking Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
DC REACTOR(DCR) Standard
Applicable safety standards UL508C, C22.2No.14, EN50178:1997(Applying)
Enclosure (IEC60529) IP00 UL open type
oling method Fan cooling
Weight / Mass[kg] 35                        
(*1) Fuji's 4-pole standard motor
(*2) Rated capacity is calculated by assuming the output rated voltage as 440V for three-phase 400V series.
(*3) Output voltage cannot exceed the power supply voltage.
(*4) When setting the carrier frequency (F26) to 1 kHz, reduce the load to 80% of its rated value.
(*5) Calculated under Fuji-specified conditions.
(*6) Obtained when a DC REACTOR is used.
(*7) Average braking torque without optional braking resistor (Varies with the efficiency of the motor.)
(*8) Voltage unbalance [%] =(Max. voltage [V] - Min. voltage [V])/(Three-phase average voltage [V])x 67 (IEC61800-3(5.2.3))
  If this value is 2 to 3%, use an AC REACTOR.
 

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC ServoSemiconductor / IGBT / Diode , Allen Bradley / Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter , PLC Cables Cisco / Cisco Router / Cisco SwitchUPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.