Model
|
IPF-90K
|
IPF-110K
|
IPF-132K
|
IPF-160K
|
IPF-220K
|
IPF-280K
|
IPF-315K
|
|
Applicable
Motor Capacity
|
90kW
|
110kW
|
132kW
|
160kW
|
220kW
|
280kW
|
315kW
|
|
Output
|
Rated
Capacity*1
|
120kVA
|
146kVA
|
175kVA
|
211kVA
|
295kVA
|
374kVA
|
409kVA
|
|
Rated
Current
|
173A
|
211A
|
253A
|
304A
|
426A
|
540A
|
590A
|
|
Overload
Current Rating
|
120%
1
min
|
|
Rated
Voltage/ Frequency
|
3Φ380V/50Hz,400V/50Hz,460V/60Hz
|
|
Input
|
Rated
Voltage/ Frequency
|
3Φ380V~460V,50Hz/60Hz
|
|
Allowable
Fluctuation
|
Voltage:
-15%,+10% Frequency:±5%
|
|
Momentary
Undervoltage Carrying
Capability
|
Above
320V,opereation last for a short rated time; below
320V, lasts for for
15msec
|
|
Protective
Structure
|
Totally
enclosed(IP20)
|
|
Forced
Air Cooling Weight
|
Forced
air cooling
|
|
Weight
|
70Kg
|
110Kg
|
110Kg
|
155Kg
|
160Kg
|
280Kg
|
280Kg
|
|
Control
Function
|
Control
Method
|
V/f
control or sensorless
vector control
|
|
High-Frequency
Carrier
|
Sine
wave PWM
|
|
Output
Frequency
Range
|
0.05
to 120 Hz (starting frequency: 0.05 to 120 Hz
variable) *
2
|
|
Frequency
Setting Resolution
|
Digital
Setting
|
0.01Hz
(0.05Hz~120Hz)
|
|
Analog
Setting
|
0.1%
(10bits for 0 to 10V, 4 to 20mA), 0.2% (9bits for 0
to 5V) for maximum output frequency*3
|
|
Frequency
Accuracy
|
Digital
Setting
|
±0.01%
of the output frequency(at
-10℃
~+
50℃
)
|
|
Analog
Setting
|
±0.2%
of the maximum output frequency(at 25±
10℃
)*3
|
|
Voltage/Frequency
Ratio(V/f)
|
Set
between base frequency 30Hz~120Hz(set
constant torque or lower the torque curve)
|
|
Torque
Compensation
|
0~10%
|
|
Acceleration/Deceleration
Features*4
|
0~6500
seconds (acceleration and deceleration can be set
independently), linear or S shaped curves can be
selected*5
|
|
DC
Braking
|
Starting
frequency(0.2Hz~20Hz),
operation time(0.1sec~10sec),
braking force(1~10
steps)
|
|
Additional
Functions
|
Flying
start, anti-breakdown during
acceleration/deceleration, momentary undervoltage
compensation, multi-speed operation, frequency jump,
re-start after momentary power-off, auto alarm
recovery, energy-saving operation, simple scheduled operation,PID
control operation, , torque limiter (for sensorless
vector control only)
|
|
Operation
Function
|
Frequency
Command Setting
|
Digital
Setting
|
Operation
panel
|
|
Analog
Setting
|
0
to 5 V, 0 to 10 V, 4 to 20 mA,
variable resistor (5 kΩ)
|
|
Input
Signals
|
Frequency
command, forward run command, reverse run command,
frequency setting methods,
acceleration/deceleration time setting, free-run
stop/alarm reset, emergency stop, multiple speeds,
jogging selection, step frequency setting, operation
signal hold, torque limiter (sensorless
vector control only)
|
|
Output
Signals
|
Contact
Output
|
Alarm
signal (
1C
contact, AC250 V,
0.3
A
)
|
|
Monitor
Signal
|
Operating,
frequency matching, overload alarm, undervoltage,
frequency approach
|
|
LED
Display
|
Frequency,
output current, synchronous rotation, line speed (no
units), alarm, capacitor charging status
|
|
Protection
Functions
|
Current
limiting, overcurrent
shutoff, motor overload, external thermal alarm, undervoltage,
overvoltage, momentary
power failure,fin
overheat, missing phase
|
|
Environment
|
Ambient
Temperature
|
-10~+
50℃
|
|
Ambient
Humidity
|
90%RH
or less (with no condensation)
|
|
Operating
Environment
|
Indoor
at
1,000
m
or lower altitude (No direct sunlight, corrosive or
inflammable gases, oil mist, or dust)
|
| |
|
|
|
|
|
|
|
|
|
|
|
|