Jonweb FA, Japan FA, 日本工控网

Always Changes For The Better! 

Panasonic, Nais PLC, Panasonic PLC, Panasonic Inverter, Panasonic Servo  Panasonic Servo and Nais PLC & Inverter, HMI ,Come from:Jonweb Technology!
中文访问    Products Center Selling Price Nais PLC Nais HMI Panasonic Servo Contact
 
Jonweb FA:
Siemens PLC & Siemens HMI, Siemens Inverter
Allen Bradley PLC
Mitsubishi PLC & Mitsubishi Inverter
Semiconductor
Yaskawa Inverter
Fuji AC Servo System
Cisco Router & Switche
 
On Requested:
Schneider PLC
Mean Well
APC UPS Power Supply
Proface HMI
LG PLC / Inverter
VIPA PLC / HMI
Sanyo Denki
BTB Inverter
Fluke Meters
Tektronix Oscilloscopes
Agilent
Hioki Tester
Panasonic
Omron
Toshiba
Hitachi
Idec
Sanken
Koyo
Meiden
Nikki Denso
Keyence
Oriental
 
Also Supply:
 -> 枕头 / 床垫
 -> Fuel Additive - STR2020
Contact Method
China/Beijing
    TeL:+86-10-86360099
            +86-10-62988280
    Fax:+86-10-62985883
MSN:
  cn5130@hotmail.com 
Email :
  ZhengJon@yahoo.com 
Any Call:
  +86-13001958500
Skype ID:  japanfa.com

More Detail...

 
GuestBook
  Send messages to us online.
Send messages to us online.
 
  
Sell your FA to China?
 
> Products Center > Nais PLC > FP0

Thermocouple unit

Features

1. Highly accurate temperature control

Overall accuracy of ±0.8°C (K, J, T range) enables highly accurate temperature control.

2. Temperature control up to 24 channels

Four and eight channel units are available to make temperature control up to 24 channels possible.

3. Easy multi-stage temperature control

By combining with PID instruction, temperature profiling control is realized.

4. Support K, J, T and R thermocouples to cover all major applications

K and J (-100 to 500°C)
T (-100 to 400°C)
R (0 to 1500°C)

Product type

Product name
Specifications
Product number
Part number
FP0 Thermocouple unit
K, J, T, R thermocouple, Resolution: 0.1°C
FP0-TC4
AFP0420
K, J, T, R thermocouple, Resolution: 0.1°C
FP0-TC8
AFP0421

Specifications

Input specifications

Item
Description
Input points
4-channel, 8-channel
(The number of input points can be changed 2, 4, 6 and 8 channels.)
Input range
Thermocouple types K and J
-100.0 to 500.0°C/-148.0 to 790.0°F note 1)
Thermocouple type T
-100.0 to 400.0°C/-148.0 to 752.0°F
Thermocouple type R
0.0 to 1500.0°C/32.0 to 1590.0°F note 1)
Digital output
K and J (when using °C): K -1000 to K 5000
K and J (when using °F): K -1480 to K 7900 note 1)
(When range over using °C: K-1001, K5001 or K8000)
(When range over using °F: K-1481, K7901 or K8000)
(When the thermocouple broken: K8000) note 2)
(Until the temperature can be measured at the initial startup: K8001) note 3)
T (when using °C): K -1000 to K 4000
T (when using °F): K -1480 to K 7520 note 1)
(When range over using °C: K-1001, K4001 or K8000)
(When range over using °F: K-1481, K7521 or K8000)
(When the thermocouple broken: K8000) note 2)
(Until the temperature can be measured at the initial startup: K8001) note 3)
R (when using °C): K 0 to K 15000
T (when using °F): K 320 to K 15900 note 1)
(When range over using °C: K0, K15001 or K16000)
(When range over using °F: K0, K15901 or K16000)
(When the thermocouple broken: K16000) note 2)
(Until the temperature can be measured at the initial startup: K16001) note 3)
Resolution
0.1°C
Sampling cycle note 5)
300 ms: when using 2 channels for an input points note 4)
500 ms: when using 4 channels for an input points note 4)
700 ms: when using 6 channels for an input points note 4)
900 ms: when using 8 channels for an input points note 4)
Overall accuracy
Range for K and J (-100 to 500°C): ±0.8°C
Range for T (-100 to 400°C): ±0.8°C
Range for R (0 to 99.9°C): ±3°C
(100 to 299.9°C): ±2.5°C
(300 to 1500°C): ±2°C
Input impedance
more than 1 M ohm
Insulation method
- Between thermocouple input terminals and control unit internal circuits:
Photo-coupler insulation/DC-DC insulation
- Between thermocouple input terminal channels: PhotoMOS relay insulation
Input/Output points
Input: 32 points note 6)

Notes
1) The measurement range available for degree Celsius is not available for degree Fahrenheit, of which the upper-limit measurement is set lower than degree Celsius, since the digital value (temperature value displayed) for degree Fahrenheit is bigger than that for degree Celsius.
2) When the thermocouple is broken, the digital value will become K8000 or K16000 within 70 seconds since broken. Practice in the ladder program a process for avoiding a risk, would be resulting from a broken thermocouple, and exchange the thermocouple.
3) Until the conversion data will be ready after the initial startup was made, the digital value shows K8001 or K16001. Those are not a temperature data. Create a ladder program, so that they are not acquired as a temperature data.
4) The settings of the input channel selection switch.
5) Conversion values for 6-time measurements (6 from the latest 8 measurements, excluding the max. and min.) are averaged, so that it takes time for the digital value to be displayed due to the rapid temperature change.
6) The control unit reads the data for 2 channels per 1 scan by the control unit. Read data by utilizing the sample program given in the product specifications and manual.

Dimensions

FP0-TC4

External dimensions
 

FP0-TC8

External dimensions
 
 

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC ServoSemiconductor / IGBT / Diode , Allen Bradley / Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter , PLC Cables Cisco / Cisco Router / Cisco SwitchUPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.