Jonweb FA, Japan FA, ÈÕ±¾¹¤¿ØÍø

Always Changes For The Better! 

Panasonic, Nais PLC, Panasonic PLC, Panasonic Inverter, Panasonic Servo  Panasonic Servo and Nais PLC & Inverter, HMI ,Come from:Jonweb Technology!
ÖÐÎÄ·ÃÎÊ    Products Center Selling Price Nais PLC Nais HMI Panasonic Servo Contact
¡¡
Jonweb FA:
Siemens PLC & Siemens HMI, Siemens Inverter
Allen Bradley PLC
Mitsubishi PLC & Mitsubishi Inverter
Semiconductor
Yaskawa Inverter
Fuji AC Servo System
Cisco Router & Switche
¡¡
On Requested:
Schneider PLC
Mean Well
APC UPS Power Supply
Proface HMI
LG PLC / Inverter
VIPA PLC / HMI
Sanyo Denki
BTB Inverter
Fluke Meters
Tektronix Oscilloscopes
Agilent
Hioki Tester
Panasonic
Omron
Toshiba
Hitachi
Idec
Sanken
Koyo
Meiden
Nikki Denso
Keyence
Oriental
¡¡
Also Supply:
 -> ÕíÍ· / ´²µæ
 -> Fuel Additive - STR2020
Contact Method
China/Beijing
    TeL:+86-10-86360099
            +86-10-62988280
    Fax:+86-10-62985883
MSN:
  cn5130@hotmail.com 
Email :
  ZhengJon@yahoo.com 
Any Call:
  +86-13001958500
Skype ID:  japanfa.com

More Detail...

¡¡
GuestBook
  Send messages to us online.
Send messages to us online.
¡¡
  
Sell your FA to China?
¡¡
> Products Center > Nais PLC > FP1 >

1. Control units
Available in a wide variation from 14 to 72 points.
For the models having more than 24 points, the C type incorporating the clock/calendar function and RS232 port is available.
¡¤ Number of points : 14/16/24/40/56/72
¡¤ Power supply : AC/DC
¡¤ Input : DC/AC (AC input is for 14-point relay output only.)
¡¤ Output : Relay/Transistor
14 points
Input 8 points/Output 6 points
16 points
Input 8 points/Output 8 points
24 points
Input 16 points/Output 8 points
40 points
Input 24 points/Output 16 points
56 points
Input 32 points/Output 24 points
72 points
Input 40 points/Output 32 points
2. Expansion units
A large variety of expansion units enables well balanced expansion in I/O. For 8-point type, the triac output type is also available.
¡¤ Number of points : 8/14/16/24/40 (For 8- point and 16-point types, the types for input only/output only/input and output mixture types are available.)
¡¤ Power supply : AC/DC (24 point- and 40-point types) (8 point- and 16-point types dispense with need for the wiring of the power supply.)
¡¤ Input : DC/AC (AC input is only for 8-point input only type and 14-point type.)
¡¤ Output : Relay/Transistor/Triac (Triac output type is for 8-point type only.)
8 points
Input only 8 points
Output only 8 points
(Relay output/Transistor output
Input 4 points/Output 4 points)
8 points
Output only 8 points
(Triac output type)
14 points
AC input 8 points
Relay output 6 points
16 points
Input only 16 points
Output only 16 points
Input 8 points/Output 8 points
24 points
Input 16 points/Output 8 points
40 points
Input 24 points/Output 16 points
3. Intelligent units
The unit exclusively for analog data input/output is available. It is used for taking in the data from the displacement sensor and controlling the inverter.
A/D converter unit (for analog input)
¡¤ Number of channels: 4
¡¤ Input range : Voltage: 0 to 5V, 0 to 10V Current: 0 to 20 mA (K0 to 1000)
¡¤ Power supply : AC/DC
D/A converter unit (for analog output)
¡¤ Number of channels: 2
¡¤ Output range : Voltage: 0 to 5V, 0 to 10V Current: 0 to 20 mA (K0 to 1000)
¡¤ Power supply : AC/DC
A/D converter
4 ch
D/A converter
2 ch
4. Link units
Remote I/O master unit, unit for I/O link with host PLC and small-scale computer link unit are available.
Transmitter master unit
¡¤ Power supply : AC/DC
I/O link unit
¡¤ Power supply : AC/DC
C-NET adapter, S1 type (for FP1 side)
¡¤ Power supply cable (30 cm 11.811 inch) is attached (Power supply not needed.)
C-NET adapter (for personal computer side)
¡¤ Power supply : AC/DC
Transmitter master unit
For remote I/O and I/O link
(MEWNET-TR compatible)
I/O link unit
For high speed PLC I/O link
(MEWNET-F compatible)
C-NET adapter S1 type
For host computer link
(to FP1)
C-NET adapter
For host computer link
(to computer)
5. Combination of units (Connection of expansion units, intelligent units)
6. Connection of expansion units

1) Control Units (C14 and C16 series)

¡¤ Number of expandable units: 1 unit
¡¤ Total number of I/O points :
C14 series: Max. 54 points
C16 series: Max. 56 points

2) Control Units (C24, C40, C56 or C72 series)

¡¤ Number of expandable units: 2 unit
¡¤ Total number of I/O points :
C24 series: Max. 104 points
C40 series: Max. 120 points
C56 series: Max. 136 points
C72 series: Max. 152 points
¡¤ If 8-point, 14-point or 16-point type expansion unit is used as primary expansion unit, only 24-point or 40-point type expansion unit can be used as secondary expansion unit.
7. Connection of intelligent units
¡¤ Number of expandable units together:
A/D converter unit: 1 unit, D/A converter unit: 2 units, I/O link unit: 1 unit
¡¤ There are no restrictions on the type and order in wich expansion units are connected.
¡¤ For the combination when using the transmitter master unit, see "FP1 MEWNET-TR MANUAL"
8. Expansion cable
¡¤ 7 cm 2.756 inch type expansion cables are attached to the expansion units, intelligent units and I/O link units.
¡¤ If you want to use 30 cm or 50 cm 11.811 inch or 19.685 inch type expansion cables, please order optionally.
¡¤ When installing the control unit and expansion unit vertically, connect the expansion cable as shown in the right figure. In this case, select the 30 cm or 50 cm 11.811 inch or 19.685 inch type cable.
¡¡

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC ServoSemiconductor / IGBT / Diode , Allen Bradley / Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter , PLC Cables Cisco / Cisco Router / Cisco SwitchUPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.