Jonweb FA, Japan FA, 日本工控网

Always Changes For The Better! 

Panasonic, Nais PLC, Panasonic PLC, Panasonic Inverter, Panasonic Servo  Panasonic Servo and Nais PLC & Inverter, HMI ,Come from:Jonweb Technology!
中文访问    Products Center Selling Price Nais PLC Nais HMI Panasonic Servo Contact
 
Jonweb FA:
Siemens PLC & Siemens HMI, Siemens Inverter
Allen Bradley PLC
Mitsubishi PLC & Mitsubishi Inverter
Semiconductor
Yaskawa Inverter
Fuji AC Servo System
Cisco Router & Switche
 
On Requested:
Schneider PLC
Mean Well
APC UPS Power Supply
Proface HMI
LG PLC / Inverter
VIPA PLC / HMI
Sanyo Denki
BTB Inverter
Fluke Meters
Tektronix Oscilloscopes
Agilent
Hioki Tester
Panasonic
Omron
Toshiba
Hitachi
Idec
Sanken
Koyo
Meiden
Nikki Denso
Keyence
Oriental
 
Also Supply:
 -> 枕头 / 床垫
 -> Fuel Additive - STR2020
Contact Method
China/Beijing
    TeL:+86-10-86360099
            +86-10-62988280
    Fax:+86-10-62985883
MSN:
  cn5130@hotmail.com 
Email :
  ZhengJon@yahoo.com 
Any Call:
  +86-13001958500
Skype ID:  japanfa.com

More Detail...

 
GuestBook
  Send messages to us online.
Send messages to us online.
 
  
Sell your FA to China?
 
> Products Center > Nais PLC > FP ∑ > Details of each unit

Communication Cassette

Features

1. Communications function added to FP SIGMA to save space.

Since the communication cassette fits inside the FP SIGMA Control Unit, a communications function can be added without consuming space on control boards.

2. Type also available with RS232C × 1ch and RS485 × 1ch.

Distributed control (RS485 data transmission) using linked PLCs, etc., is possible while using RS232C to communicate with standalone devices
(for example an Image checker).

Product types

Product name
Specifications
Product number
Part number
FP SIGMA 1-channel, RS232C type
Communication cassette
Cassette for control unit installation.
Enables communications with devices with RS232C interface.
FPG-COM1
AFPG801
FP SIGMA 2-channel, RS232C type
Communication cassette
Cassette for control unit installation.
Enables communications with devices with RS232C interface.
FPG-COM2
AFPG802
FP SIGMA 1-channel, RS485 type
Communication cassette
Cassette for control unit installation.
PLC linking between FP SIGMAs or communication with devices
with RS485 interface possible or PLC link between FP SIGMAs.
FPG-COM3
AFPG803
FP SIGMA 1-channel, RS232C and
1-channel, RS485 type
Communication cassette
Cassette for control unit installation.
Enables communications with devices with RS232C or RS485 interface.
FPG-COM4
AFPG806

Specifications

Serial communication Specifications (1:1 communication) note 1)

Item
Description
Communication method
Half duplex
Synchronous method
Asynchronous method
Transmission line
3-core or 5-core shielding cable
Transmission distance
15 m 49.21 ft.
Transmission speed (Baud rate)
2400 bits/s to 115.2 k bits/s
Interface
Conforming to RS232C
(connected via the terminal block)

Note 1) In order to use the serial communication function (1:1 communication), a RS232C type communication cassette is required.

Serial communication Specifications (1:N communication) note 1)

Item
Description
Communication method
Two-wire, half duplex
Synchronous method
Asynchronous method
Transmission line
Shielding twisted-pair cable or VCTF
Transmission distance
(Total distance)
Maximum 1200 m 3937 ft.note 4) 5)
Transmission speed
(Baud rate)
2400 bits/s to 115.2 k bits/s
19200 bits/s when a C-NET adapter is connected note 2) 4) 5)
Number of connected
units (stations)
Maximum 99 units (stations)
32 units (stations) max. when a C-NET adapter is
connected note 3) 4) 5)
Interface
Conforming to RS485
(connected via the terminal block)

Notes 1) In order to use the serial communication function (1:N communication), a RS485 type communication cassette is required.
2) The transmission speed (baud rate) and transmission format are specified using the system registers.
3) Unit (station) numbers are specified using the system registers. Up to 31 units (stations) can be set, using the switches on the control unit.
4) When connecting a commercially available device that has an RS485 interface, please confirm operation using the actual device. In some cases, the number of units (stations), transmission distance, and transmission speed (baud rate) vary depending on the connected device.
5) The values for the transmission distance, transmission speed (baud rate), and number of units (stations) should be within the values noted in the graph below.

PLC link function Specifications note 1)

Item
Description
Communication method
Token bus
Transmission method
Floating master method
Transmission line
Shielding twisted-pair cable or VCTF
Transmission distance (Total distance)
1200 m 3937 ft.
Transmission speed (Baud rate)
115.2 k bits/s
Number of connected units (stations)
Maximum 16 units note 2)
PLC link capacity
Link relay: 1024 points, link register: 128 words
Interface
Conforming to RS485 (connected via the terminal block)

Notes 1) A RS485 type communication cassette is required in order to use the PLC link function.
2) Unit (station) numbers are specified using the switches on the control unit or the system registers.

Dimensions

When the communication cassette is used

External dimensions
 
 
 

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC ServoSemiconductor / IGBT / Diode , Allen Bradley / Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter , PLC Cables Cisco / Cisco Router / Cisco SwitchUPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.