Jonweb FA, Japan FA, 日本工控网

Always Changes For The Better! 

Panasonic, Nais PLC, Panasonic PLC, Panasonic Inverter, Panasonic Servo  Panasonic Servo and Nais PLC & Inverter, HMI ,Come from:Jonweb Technology!
中文访问    Products Center Selling Price Nais PLC Nais HMI Panasonic Servo Contact
 
Jonweb FA:
Siemens PLC & Siemens HMI, Siemens Inverter
Allen Bradley PLC
Mitsubishi PLC & Mitsubishi Inverter
Semiconductor
Yaskawa Inverter
Fuji AC Servo System
Cisco Router & Switche
 
On Requested:
Schneider PLC
Mean Well
APC UPS Power Supply
Proface HMI
LG PLC / Inverter
VIPA PLC / HMI
Sanyo Denki
BTB Inverter
Fluke Meters
Tektronix Oscilloscopes
Agilent
Hioki Tester
Panasonic
Omron
Toshiba
Hitachi
Idec
Sanken
Koyo
Meiden
Nikki Denso
Keyence
Oriental
 
Also Supply:
 -> 枕头 / 床垫
 -> Fuel Additive - STR2020
Contact Method
China/Beijing
    TeL:+86-10-86360099
            +86-10-62988280
    Fax:+86-10-62985883
MSN:
  cn5130@hotmail.com 
Email :
  ZhengJon@yahoo.com 
Any Call:
  +86-13001958500
Skype ID:  japanfa.com

More Detail...

 
GuestBook
  Send messages to us online.
Send messages to us online.
 
  
Sell your FA to China?
 
> Products Center > Nais PLC > FP3/FP10SH
A/D Converter Unit (For Analog Input)

Features

Advantages of G type

1. 8 input channels available in a unit
The multi-channel input system reduces the number of slots.

2. Economical design
Non-insulated interchannel design brings cost reduction.

Advantages of I type

1. Insulated between channels
Insulated between channels, the unit is not affected by the potential difference at the input equipment side.

2. 8 input channels available in a single unit
The multi-channel input system reduces the number of slots used.

3. Voltage/current input is selectable for each channel
The selection of voltage/current input can be made by the dip switch.

Advantages of C type

1. Equipped with averaging function
This function reduces the in uence of noise and an unstable input signal.

2. Scale converting function
This function converts into desired format of data by changing the full-scale and offset points.

3. Alarm function
It is possible to set the upper and lower limits and feed back the alarm signal.

4. 4 ranges are available.
The ranges can be changed with the dip switch on the unit.

Product Types

Product name
Specifications
Part number
A/D Converter Unit
G type
8-channel,
non-insulated
Input range: -10 to +10 V --> -4000 to +4000 (resolution 1/8000)
Response time: 20 ms or less/channel
AFP3402
Input range: 1 to 5 V --> 0 to +8000 (resolution 1/8000)
Response time: 20 ms or less/channel
AFP3403
Input range: 4 to 20 mA --> 0 to +8000 (resolution 1/8000)
Response time: 20 ms or less/channel
AFP3405
I type
8-channel,
insulated
Input range: 1 to 5 V --> 0 to +8000 (resolution 1/8000)
Input range: 4 to 20 mA --> 0 to +8000 (resolution 1/8000)
Response time: 20 ms or less/channel
AFP3406
Input range: 0 to 5 V --> 0 to +8000 (resolution 1/8000)
Input range: 0 to 20 mA --> 0 to +8000 (resolution 1/8000)
Response time: 20 ms or less/channel
AFP3407
Input range: -10 to 10 V --> -4000 to +4000 (resolution 1/8000)
Input range: -20 to 20 mA --> -4000 to +4000 (resolution 1/8000)
Response time: 20 ms or less/channel
AFP3408
C type
4-channel,
non-insulated
Input range: -10 to +10 V --> -2000 to +2000 (resolution 1/4000)
Input range: 1 to 5 V --> 0 to +4000 (resolution 1/4000)
Input range: -20 to +20 mA --> -1000 to +1000 (resolution 1/2000)
Input range: 4 to +20 mA --> 0 to +4000 (resolution 1/4000)
Scaling, averaging function, warning signal
Response time: 2.5 ms or less/1 channels
AFP3400

Specifications

Performance Specifications

G type
Item
AFP3405
AFP3403
AFP3402
Analog input channels
8 ch/unit
Analog input range
4 to 20mA DC
1 to 5V DC
-10 to +10V DC
Digital converted range
k0 to k8000
k-4000 to k+4000
Resolution
1/8000
Overall accuracy
1% of full scale
(at 0°C to 55°C 32 ° F to 131 ° F)
Response time
20 ms or less/1 ch *
Input impedance
Input impedance Voltage 1 M ohm or more
Current 250 ohm
Absolute input range
Voltage +15 V
Current +30 mA
Insulation method
(1) Optical coupler insulation between analog input terminal and internal circuit
(2) Not insulated between analog input channels
Connected method
Terminal block (M3.5 screw)
Averaging function
Not available
Digital data scaling function
Not available
Warning signal function
Not available
Weight
Approx. 400 g 14.110 oz

Notes:
*1) The range can be selected by the dip switch for each channel.
*2) The range cannot be set for each channel.
*3) A/D conversion time varies with the number of effective channels.

I type
Item
AFP3406
AFP3407
AFP3408
Analog input channels
8 ch/unit
Analog input range
4 to 20 mA
DC or 1 to 5
V DC *
0 to 20 mA
DC or 0 to 5
V DC *
-20 to +20 mA DC or
-10 to +10 V DC *
Digital converted range
k0 to k8000
k-4000 to k+4000
Resolution
1/8000
Overall accuracy
1% of full scale
(at 0°C to 55°C 32 ° F to 131 ° F)
0.5% of full scale (at 25°C 77 ° F)
Response time
20 ms or less/1 ch *
Input impedance
Voltage 1 M ohm or more
Current 250 ohm
Voltage 1 M ohm or more
Current 500 ohm
Absolute input range
Voltage +15 V
Current +30 mA
Insulation method
(1) Optical coupler insulation between analog input terminal and internal circuit
(2) Optical MOS relay insulation between analog input channels
Connected method
Terminal block (M3.5 screw)
Averaging function
Not available
Digital data scaling function
Not available
Warning signal function
Not available
Weight
Approx. 400 g 14.110 oz

Notes:
*1) The range can be selected by the dip switch for each channel.
*2) The range cannot be set for each channel.
*3) A/D conversion time varies with the number of effective channels.

C type
Item
AFP3400
Analog input channels
4 ch/unit
Analog input range
Analog input range -10 to 0 to +10V DC
1 to 5V DC
Selective range by the DIP switch note 2)
Current: -20 to 0 to +20mA DC
4 to +20mA
Selective range by the DIP switch note 2)

Selected by the input terminal
Digital converted range
k-2000 to k+2000 or k0 to k+4000
Resolution
1/4000 (1/2000 at -20 mA to +20 mA)
Overall accuracy
±1.0% of full scale (at 0°C to 55°C 32 ° F to 131 ° F)
±0.5% of full scale (at 25°C 77 ° F)
Response time
2.5 ms/channel note 3)
Input impedance
Voltage 1 M ohm or more
Current 250 ohm
Absolute input range
(±10 V range) (1 to 5 V range)
Voltage ±15V+7.5 V
Current ±30mA+30mA
Insulation method
(1) Optical coupler insulation between analog input terminal and PLC power supply
(2) Not isolated between analog input channels
Connected method
Terminal block (M3.5 screw)
Averaging function
3 to 4000 times
Digital data scaling function
Scaling the digital converted range from k-32768 to k+32767
Warning signal function
Upper/Lower limits setting for each channel
Weight
Approx. 400 g 14.110 oz

Notes:
*1) The range can be selected by the dip switch for each channel.
*2) The range cannot be set for each channel.
*3) A/D conversion time varies with the number of effective channels.
 

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC ServoSemiconductor / IGBT / Diode , Allen Bradley / Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter , PLC Cables Cisco / Cisco Router / Cisco SwitchUPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.