Pulse
Output Unit
-

Features
1. Easy positioning control
The pulse output unit has a two-stage frequency
setting.
Using this function together with a pulse-string
input driver facilitates positioning control.
-

2. Pulse output frequency can be selected with
control knob
The two-stage pulse output frequency range and
change-over time can be set with the control knob on the unit.
3. Adjustable by external input
Pulse output can be stopped and frequency range
changed over by external input.
4. Home return function
With home return input (ZERO) and near home input
(SUB), the unit offers automatic home return.
5. Processing is speeded up by an interrupt
program
Starting an interrupt program when target value is
reached, speeds up processing time.
Product Types
|
Product name
|
Speci cations
|
Part number
|
|
FP3 Pulse Output Unit
|
Pulse motor
Pulse output for controlling servomotor
(Low frequency: 200 Hz to 5 kHz, High
frequency: 3 k to 40 kHz)
Pulse output counter
|
AFP3480 |
Configuration
-

Specifications
Performance Specifications
|
Item
|
Description
|
|
Output
|
Pulse output
|
Output points
|
2 points (OUT 0, OUT 1)
|
|
Output mode
|
1 pulse mode/2 pulse mode
|
|
Output frequency
|
|
200 Hz to 40 kHz (Duty: 50%±25%,
Variation: ±5%)
|
|
Low frequency
|
200 Hz to 5 kHz
|
|
High frequency
|
3 to 40 kHz
|
|
Switching time
|
100 to 500ms
|
|
Input
|
Input points
|
4 points (RST, P.OUT, ZERO, SUB)/channel
|
|
Input voltage
|
5 to 24 V DC
|
|
Min. ON voltage/Min. ON current
|
4.5V/3mA
|
|
Max. OFF voltage/Max. OFF current
|
1.5V/0.6mA
|
|
Output
|
Output points
|
2 points (C=P,C>P)
|
|
Output type
|
Transistor output (NPN, Open collector)
|
|
Rated operating voltage
|
5 to 24V DC
|
|
Max. load current
|
0.1A
|
|
Counting range
|
-16,777,216 to +16,777,215
(using 24 bits binary including sign bit)
|
|
Weight
|
Approx. 400 g 14.110
oz
|
|